PacketFence
Bug Tracking System

View Issue Details Jump to Notes ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0001664PacketFencehardware modulespublic2013-07-09 16:032015-02-18 10:59
Reporterdgreer 
Assigned To 
PrioritynormalSeveritymajorReproducibilityalways
StatusclosedResolutionopen 
PlatformOSOS Version
Product Version4.0.1 
Target VersionFixed in Version 
Summary0001664: On Extreme, does not support port numbers in the form "X:Y" for Uplinks
DescriptionWhen adding a switch that is stacked (or a chassis), Extreme uses the port numbering format 'X:Y', where X is the unit or card number, and Y is the port on that unit/card. The verification of the port number list on the Uplinks line does not allow ports entered in this formation.

This is a show stopper for anybody using enterprise-class installations of Extreme devices.
TagsNo tags attached.
fixed in git revision
fixed in mtn revision
Attached Files

- Relationships

-  Notes
(0003338)
roadracer96 (reporter)
2013-07-11 07:46

Just use standard XY notation X is the stack unit, Y is the port padded with 0s to 3 digits. So port 2:46 would be 2046. This is how Extreme sends the information in RADIUS requests and it is how it expects any replies.
(0003947)
lmunro (administrator)
2015-02-18 10:59

Obsolete bug tracker entries.
PF 4 introduced changes that either make these irrelevant or impossible to reproduce.

New issues are moving to github issues.

- Issue History
Date Modified Username Field Change
2013-07-09 16:03 dgreer New Issue
2013-07-11 07:46 roadracer96 Note Added: 0003338
2015-02-18 10:59 lmunro Note Added: 0003947
2015-02-18 10:59 lmunro Status new => closed